The different Cisco links states Cisco 2811 supports: 4 HWIC slots, 1 expansion network module slot, 2 PVDM slots, 2 AIM slots As you suggested NM-HD-2V-(E in function of the needs) is the most appropriate choice in your scenario and supports two VIC3-2E/M =. Cisco 2811 - router - desktop overview and full product specs on CNET. Holiday Gift Guide 2020. Best gifts under $30. Expansion Slots.

This post explains the interface numbering scheme used in Cisco 1800, Cisco 2800 and Cisco 3800 Series Routers. It also includes line numbering associated with async interfaces.

Existing router platforms (earlier than Cisco 1800, Cisco 2800, and Cisco 3800) contain a limitation. In some situations, such as when you insert WIC(s) out of order, the configuration of one WIC interface can be lost or applied to another WIC interface.

Example: Assume that you have a serial WIC-2T in WIC slot 1 and WIC slot 0 is empty. The interfaces are named serial 0/0 and serial 0/1. If you insert another WIC-2T into slot 0, the new WIC interfaces are named serial 0/0 and serial 0/1. The old WIC interfaces become serial 0/2 and serial 0/3. Therefore, the old WIC interface configuration moves to the new WIC interfaces.

Refer to How Async Lines are Numbered in Cisco 3600 Series Routers for more information.

In order to overcome this limitation, Cisco 1800, Cisco 2800, and Cisco3800 series platforms now have a three-tiered interface numbering format (slot/subslot/port) for interfaces on WIC slots only.

Note: The slot information for the Cisco 3800 series is the same as the 2800/1800 interface and line numbering. See New Interface and Line Number Conventions for information on interface and line numbering.

New Interface and Line Number Conventions

This section describes the new conventions for interface and line numbering.

  1. The interface numbering scheme is the same for async interfaces and non-async interfaces. To configure the line associated with an async interface, use the interface number to specify the async line.For example, line 0/0/0 specifies the line associated with interface serial 0/0/0 on a WIC-2A/S in slot 0. Similarly, line 0/1/1 specifies the line associated with interface async 0/1/1 on a WIC-2AM in slot 1.

    Note: This document uses the following words interchangeably:

    • Network-module-slot and slot.
    • Interface-card-slot and subslot.
  2. Ports on network modules are numbered like this:interface-number = network-module-slot/port

    OR

    interface-number = slot/port

  3. Ports on interface cards (such as WICs, VWICs and HWICs) installed directly in chassis slots is given here:interface-number = 0/interface-card-slot/port

    OR

    interface-number = 0/subslot/port

  4. This numbering convention is used for ports on interface cards that are installed in network module slots:interface-number = network-module-slot/interface-card-slot/port

    OR

    interface-number = slot/subslot/port

    Note: The slot/subslot/port format only applies to WIC interfaces. Interfaces that are native to the network modules still use only the slot/port format. That is:

    • <interface-name> slot/port is used whenever the interfaces are native on the network module.
    • <interface-name> slot/subslot/port is used whenever the interfaces are on the WIC slot of a network module (NM).
  5. Here is an example for numbering when the motherboard slot number is always 0. The native interfaces on the motherboard are numbered like this:
    • Fa0/0, Fa0/1 on Cisco 2811.
    • Gi0/0, and Gi0/1 on Cisco 2821 and Cisco 2851.

    The Motherboard WIC slots are numbered from 0 to 3. The number increments from right to left, and from bottom to top.

  6. Slot numbers for other slots increase from bottom to top, then right to left. Subslot numbers and port numbers within a slot also increase from bottom to top, then right to left.

Examples

Interfaces native to an extension network module (ENM):

If the ENM carries WIC cards, the WIC slot numbers start from 0:

The extension voice module (EVM) slot analog interfaces are numbered from voice-port 2/0/0 to voice-port 2/0/23, following the NM-HDA convention.

Interface Numbering

This section lists the interface numbering details for Cisco routers.

Table 1 – Interface Numbering on Cisco 1841

Cisco 2811 Slots Game

Cisco 2811 Platform

Figure 1 shows the interface numbering on Cisco 2811 platform with:

  • HWICD-9FE in WIC slot 1.
  • VWIC-2MFT-T1 in WIC slot 2.
  • VIC2-2FXS in WIC slot 3.
  • NM-HDV2-1T1/E1 which has 1 NATIVE T1/E1 port & VWIC-2MFT-T1 in its WIC slot 0.

Figure 1 – Interface Numbering on Cisco 2811 Platform

Cisco 2811 Latest Ios

Cisco 2851 Platform

Figure 2 shows the interface numbering on Cisco 2851 platform with:

  • HWIC-1GE in WIC slot 0.
  • HWIC-4T in WIC slot 1.
  • WIC-1SHDSL in WIC slot 2.
  • VWIC-2MFT-T1 in WIC slot 3.
  • NMD-36ESW in ENM slot 1 and EVM-HD-8FXS/DID in EVM slot.

Figure 2 – Interface Numbering on Cisco 2851 Platform

Slots on Cisco 1841, 2801, 2811, 2821, 2851 Routers

This section illustrates the positions of the various slots on Cisco 1841, 2801, 2811, 2821, 2851 routers.

Figure 3 – Rear Panel of the Cisco 1841 Router

Figure 6 – Rear Panel of Cisco 2811 Router

Cisco 2811 Slots Download

http://www.cisco.com/c/en/us/support/docs/routers/3725-multiservice-access-router/62611-c2800-62611.html

General Information
ManufacturerCisco Systems, Inc
Manufacturer Part NumberCISCO2811
Brand NameCisco
Product Series2800
Product Model2811
Product Name2811 Router
Marketing Information

The Cisco 2811 provides significant additional value compared to prior generations of Cisco routers at similar price points by offering up to a fivefold performance improvement, up to a tenfold increase in security and voice performance, new embedded service options, and dramatically increased slot performance and density while maintaining support for most of the more than 90 existing modules that are available today for the Cisco 1700, Cisco 2600, and Cisco 3700 Series.

Product TypeRouter
Interfaces/Ports
Total Number of Ports2
USBYes
Management PortYes
Number of Network (RJ-45) Ports2
I/O Expansions
Number of Total Expansion Slots9
Expansion Slot Type
  • AIM
  • HWIC
  • NME
  • PVDM
Network & Communication
Network Technology10/100Base-TX
Ethernet TechnologyFast Ethernet
Memory
Standard Memory256 MB
Maximum Memory760 MB
Memory TechnologyDRAM
Flash Memory64 MB
Power Description
Input Voltage
  • 110 V AC
  • 220 V AC
Physical Characteristics
Compatible Rack Unit1U
Form Factor
  • Rack-mountable
  • Wall Mountable
Height1.8'
Width17.3'
Depth16.4'
Miscellaneous
Package Contents
  • 2811 Router
  • Power Cord, 110V (CAB-AC)
  • Cisco 2800 IOS IP BASE
  • Device manager for routers (ROUTER-SDM)
  • 256MB DDR DRAM Memory factory default for the Cisco 2800 (MEM2800-256D-INC)
  • 64MB CF default for Cisco 2800 Series (MEM2800-64CF-INC)
  • Blank WAN Interface Card Panel (WIC-BLANK-PANEL)
  • Cisco 2800 and 3800 Series Blank network module panel (NM-28/38BLNK-PANEL)
  • Cisco 2811 AC power supply (PWR-2811-AC)
  • RJ-45-to-DB-9 console cable and RJ-45-to-DB-25 modem cable for management access
  • One pair of rack-mount brackets with screws for 19-inch racks
  • Cisco Product Registration Card
  • Cisco 2800 Series Regulatory Compliance and Safety Information document
  • Cisco Router and Security Device Manager (SDM) Quick Start Guide document
  • Cisco 2800 Series Integrated Services Routers Quick Start Guide
Additional Information

Interface Card Slots:

  • Each slot can support HWIC, WIC, VIC, or VWIC type modules

RPS:

  • External only, connector for RPS provided by default

Operation Altitude (derate 1.5°C per 1000 ft):

  • 27.5°C @ 15 kft
  • 35°C @ 3km/10 kft
  • 40°C @ sea level
Certifications & Standards
  • IEEE 802.3: 10BASE-T
  • IEEE 802.3u: 100BASE-TX
  • USB 1.1

Safety:

  • UL 60950
  • CAN/CSA C22.2 No. 60950
  • IEC 60950
  • EN 60950-1
  • AS/NZS 60950

Immunity:

  • EN300386
  • EN55024/CISPR24
  • EN50082-1
  • EN61000-6-2

EMC:

  • FCC Part 15
  • ICES-003 Class A
  • EN55022 Class A
  • CISPR22 Class A
  • AS/NZS 3548 Class A
  • VCCI Class A
  • EN 300386
  • EN61000-3-3
  • EN61000-3-2

TELCOM:

  • Interfaces comply with FCC Part 68, CS-03, JATE Technical Conditions, European Directive 99/5/EC and relevant TBR's